Vermiculite Lightweight Concrete: Insulating Concrete with Polystyrene Ventboard
This system of superior insulating value consists of polystyrene board and vermiculite insulating concrete applied
over structural bases of regular concrete, metal or wood. This system provides flexibility that will meet most design
criteria. Insulating values can be varied by changing the thickness of the polystyrene board. Proper slope to drain
can be obtained with the vermiculite concrete. Minimum thickness of the concrete shall be two inches. |
| "U" Factor Table (includes Built-up Roofing) |
| Thickness of Concrete over Ventboard | Thickness of Ventboard | Wt. Lbs. Per Sq. Ft.(Mtl.-Vent Bd. Concrete) | Depth of Corrugation 9/16" - 28 Gauge |
Wt.Lbs. Per Sq. Ft.(Mtl.- Vent Bd. Concrete) | Depth of Corrugation 7/8" -- 26 Gauge |
Wt. Lbs. Per Sq. Ft. (Mtl.- Vent Bd. Concrete) | Depth of Corrugation 1-5/16" - 24 Gauge |
|||||||||
| No Ceiling Heat Flow |
Ceiling Heat Flow |
No Ceiling Heat Flow |
Ceiling Heat Flow |
No Ceiling Heat Flow |
Ceiling Heat Flow |
|||||||||||
| Up | Down | Up | Down | Up | Down | Up | Down | Up | Down | Up | Down | 2" | 3/4" | 5.64 | .13 | .12 | .086 | .083 | 6.29 | .13 | .12 | .084 | .081 | 7.06 | .12 | .11 | .081 | .079 |
| 1" | 5.66 | .11 | .11 | .079 | .076 | 6.31 | .11 | .11 | .077 | .075 | 7.08 | .11 | .10 | .075 | .073 | |
| 2" | 5.75 | .077 | .075 | .059 | .058 | 6.41 | .075 | .073 | .058 | .057 | 7.18 | .073 | .071 | .057 | .056 | 2 1/2" | 3/4" | 6.68 | .12 | .11 | .080 | .078 | 7.33 | .11 | .11 | .078 | .076 | 8.10 | .11 | .10 | .076 | .074 |
| 1" | 6.70 | .11 | .10 | .074 | .072 | 7.35 | .10 | .098 | .072 | .070 | 8.12 | .098 | .094 | .071 | .069 | |
| 2" | 6.80 | .073 | .071 | .056 | .055 | 7.45 | .071 | .069 | .055 | .054 | 8.22 | .069 | .068 | .054 | .053 | |
| Notes: |
|
| |